DN15 Instrument instrument Ultrasonic heat meter
Hebei Xiangyuan Instrument Technology Co., Ltd.
Summary Description
1.Minimum flow: 0.03
2.Commonly Used Flow: 1.5
3.Maximum flow: 3
$33.00
PRODUCT DETAILS
Company Profile
Hebei Xiangyuan Instrument Technology Co ., Ltd . is a professional enterprise engaged in the research and production of water meters , heat meters ( coldand hot meters ), flow meters , and intelligent control valves . It is a high - tech enterprise with internatio nal excellent design , research and development , and manufacturing capabilities , with strong financial and technical strength . Its headquarters is located in Shijiazhuang , the capital of Hebei Province .
Since its establishment , the enterprise has achieved rapid and healthy development by strengthening external technological cooperation , focusing on technological innovation and new product development . The performance indicators of the heat meter and intelligent water meter series products developed and produced have fully met industry standards .
In the face of the challenges of the new century , Xiangyuan has always taken revitalizing national industry as its own bility , wittheaimof " serving a new society with new technology ", advocating for a trustworthy and efficient work style , and winning the trust of a large number of users with excellent product quality , stable technical performance , and perfect after - sales service . We look forward to working together with you to promote the continuous development of intelligent community construction in China.
Elite team
Innovation not only means progress and development , but also contains opportunities and risks . Facing the challenges in the future , we can ' t help thinking a famous saying " either stand up to bear , otherwise lay down to lost all ". We achived recreation and re - innovation in the operaton by technology . guided our enterpries ' s development by mordenalized management .
We have applied this spirt in every unit . of the enterprise . Our team is strong and tacit . The flag of leadship is belong to us .
Modern Chinese Dictionary wrote " success is to achive the desired results ". Creation and pursuit of excellence is our goal that we have been insisted . We strongly believe that " Gentleman has persistent spirit owing to the strong of nature " we will finally achived our goal .
Company qualification
Product details and parameters
|
|
Nominal calibre(mm) | DN15 | DN20 | DN25 | DN32 | DN40 |
Minimum flow(mn) | 0.03 | 0.05 | 0.07 | 0.12 | 0.20 |
Commonly Used Flow(qp) | 1.5 | 2.5 | 3.5 | 6.0 | 10.0 |
Maximum flow(qmax) | 3 | 5 | 7 | 12 | 20 |
Temperature range | (4-95)℃ | Installation position | Intake / Return | ||
Temperature difference range | (3-75)K | Installation mode | Ping An installation / vertical installation | ||
Work pressure | ≤1.6MPa | Scheme of electric power supply | 3.6V lithium battery powered | ||
Pressure loss | ≤0.025MPa | Battery life | ≥ 6 years | ||
Order of accuracy | 2 level | Static power consumption | ≤10μ A | ||
Environmental grade | A level | Length of temperature sensing line | 1.5M |
|
|
Nominal calibre(mm) | DN15 | DN20 | DN25 | |
Minimum flow(mn) | 0.03 | 0.05 | 0.07 | |
Commonly Used Flow(qp) | 1.5 | 2.5 | 3.5 | |
Maximum flow(qmax) | 3 | 5 | 7 | |
Temperature range | (4-95)℃ | Installation position | Intake / Return | |
Temperature difference range | (3-75)K | Installation mode | Ping An installation / vertical installation | |
Work pressure | ≤1.6MPa | Scheme of electric power supply | 3.6V lithium battery powered | |
Pressure loss | ≤0.025MPa | Battery life | ≥ 6 years | |
Order of accuracy | 2 level/3 level | Static power consumption | ≤10μ A | |
Environmental grade | A level | Length of temperature sensing line | 1.5M |
|
|
Nominal calibre(mm) | DN50 | DN65 | DN80 | DN100 |
DN125 |
DN150 |
DN200 | DN250 |
Minimum flow(mn) | 0.6 | 1.0 | 1.6 | 2.4 | 4.0 | 6.0 | 10.0 | 16.0 |
Commonly Used Flow(qp) | 15 | 25 | 40 | 60 | 100 | 150 | 250 | 400 |
Maximum flow(qmax) | 30 | 50 | 80 | 120 | 200 | 300 | 500 | 800 |
Temperature range | (4-95)℃ | Installation position | Intake / Return | |||||
Temperature difference range | (3-75)K | Installation mode | Ping An installation / vertical installation | |||||
Work pressure | ≤1.6MPa | Scheme of electric power supply | 3.6V lithium battery powered | |||||
Pressure loss | ≤0.025MPa | Battery life | ≥ 6 years | |||||
Order of accuracy | 2 level/3 level | Static power consumption | ≤10μ A | |||||
Environmental grade | A level | Length of temperature sensing line | 1.5M |
|
|
Nominal calibre(mm) | DN300 | DN350 | DN400 | DN450 | DN500 |
Minimum flow(mn) | 24.0 | 30.0 | 40.0 | 48.0 | 60.0 |
Commonly Used Flow(qp) | 600 | 750 | 1000 | 1200 | 1500 |
Maximum flow(qmax) | 1200 | 1500 | 2000 | 2400 | 3000 |
Temperature range | (4-95)℃ | Installation position | Intake / Return | ||
Temperature difference range | (3-75)K | Installation mode | Ping An installation / vertical installation | ||
Work pressure | ≤1.6MPa | Scheme of electric power supply | 3.6V lithium battery powered | ||
Pressure loss | ≤0.025MPa | Battery life | ≥ 6 years | ||
Order of accuracy | 2 level | Static power consumption | ≤10μ A | ||
Environmental grade | A level | Length of temperature sensing line | 1.5M |
|
|
Nominal calibre(mm) | R value | Overcurrent flow | Commonly Used Flow | Boundary flow | Minimum flow | L | W | H |
DN50 | 50 | 31.25 | 25 | 0.8 | 0.5 | 275 | 125 | 156 |
DN80 | 50 | 78.75 | 40 | 1.3 | 0.8 | 225 | 200 | 230 |
DN100 | 50 | 125 | 60 | 2.1 | 1.26 | 250 | 220 | 250 |
DN150 | 50 | 312.5 | 150 | 5.2 | 3.2 | 300 | 280 | 305 |
DN200 | 50 | 500 | 200 | 30 | 4.0 | 350 | 340 | 355 |
|
|
Nominal calibre(mm) | R value | Overcurrent flow | Commonly Used Flow | Boundary flow | Minimum flow | L | W | H |
DN50 | 80 | 31.25 | 25 | 2.0 | 0.3125 | 200 | 170 | 215 |
DN65 |
80 | 50 | 40 | 3.2 | 0.5 | 200 | 185 | 220 |
DN80 | 80 | 78.75 | 63 | 5.2 | 0.7875 | 225 | 200 | 280 |
DN100 | 80 | 125 | 100 | 8.0 | 1.25 | 250 | 220 | 290 |
DN125 |
80 | 200 | 160 | 12.8 | 2.0 | 350 | 250 | 300 |
DN150 | 80 | 312.5 | 250 | 20.0 | 3.125 | 300 | 285 | 360 |
DN200 | 80 | 500 | 400 | 32.0 | 5.0 | 350 | 340 | 385 |
DN250 |
80 | 788 | 630 | 50.4 | 7.875 | 450 | 400 | 450 |
DN300 |
80 | 1250 | 1000 | 80.0 | 1.25 | 500 | 450 | 480 |
Engineering case
![]() |
![]() |
1.Shanghai Tower 2.Guangzhou TV Tower 3.Peking University 4.Beijing Bird's Nest 5.Chengdu Shuangliu Airport 6.Wangfujing 7.Saudi Arabia Pavilion 8.South America 9.Waikuku 10.Hilton Grand Hotel 11.New Delhi Shopping Centre 12.Daya Bay Nuclear Power Plant 13.Shanghai Yaohan Shopping Center 14.Guiyang Longdongbao Airport 15.Pepsico Guangzhou 16.Tsingtao Beer 17.Nongfu Spring in Hangzhou 18.Gree Group 19.Shanghai Sports Museum |
FAQ
Q: How can I make order online?
A: Send email or message(whatsApp/ wechat) us.you can ask any question ,after we confirm the detail, we can make order.
Q: Do you have MOQ limit?
A: The MOQ is 1 set.
Q: Which payments are acceptable?
A: T/T, L/C, Western Union, Paypal.
Q: Which shipping terms are available?
A: By sea, air, Express.
Q: How about the delivery time?
A: Delivery time is normally 3-7 working days after confirm the money. Depends on your quantity.
Q: What's your warranties?
A: 1 year after delivery.
Q: Can I buy parts separately?
A: Yes, all of the pump spare parts can buy separately.
Message